Y-type of Stenting for Revision of a Transjugular Intrahepatic Portosystemic Shunt (TIPS): A Case Report
DOI:
https://doi.org/10.14738/bjhr.1202.18734Keywords:
transjugular intrahepatic portosystemic shunt, TIPS, revision, parallel TIPS, stent thrombosis, Viatorr stentAbstract
Purpose: To describe the technique of y-stenting in a patient receiving TIPS revision for thrombotic shunt occlusion. Methods: This report describes a patient receiving TIPS for refractory ascites. At primary implantation, the stent migrated slightly towards the inferior caval vein, a plausible explanation for thrombotic stent occlusion and partial thrombosis of the inferior caval vein. Refractory ascites recurred indicating TIPS revision which was performed after a 2-week anticoagulation treatment. At revision, catheterization of the stent failed and a parallel TIPS was discussed, but eventually disregarded because of a very narrow intrahepatic portal branch which was completely occupied by the former Viatorr stent. Result: A y-type of stenting was performed by lateral puncture of the Viatorr stent and implantation of an additional stent through the wall of the primary stent. The intervention was uncomplicated, reduced the portosystemic gradient effectively, and resulted in complete clinical response. Conclusions and clinical significance: This case demonstrates the feasibility of y-stenting. The technique may be superior to parallel stenting because it avoids the risk of parenchymal and portal vein injury.
References
Haskal ZJ, Davis A, McAllister A, Furth EE. PTFE-encapsulated endovascular stent-graft for transjugular intrahepatic portosystemic shunts: experimental evaluation. Radiology 1997;doi.org/10.1148/radiology.205.3.9393521
Haskal ZJ. Improved patency of transjugular intrahepatic portosystemic shunts in humans: creation and revision with polytetrafluoroethylene (PTFE) stent-grafts. Radiology 1999; DOI.org/10.1148/radiology.213.3r99dc28759
Wang L, Xiao Z, Yue Z, et al. Efficacy of covered and bare stent in TIPS for cirrhotic portal hypertension: A single center randomized trial. Scientific reports 2016; DOI: 10.1038/srep21011
Rössle M, Siegerstetter V, Euringer W, et al. The use of a polytetrafluoroethylene-covered stent graft for transjugular intrahepatic portosystemic shunt (TIPS): Long-term follow-up of 100 patients. Acta Radiol 2006;47:660-666.
Bercu ZL, Fischman AM, Kim E, et al. TIPS for refractory ascites: a 6-year single-center experience with expanded polytetrafluoroethylene-covered stent-grafts. AJR 2015;204:654-661.
Bureau C, Garcia-Pagan JC, Layrargues GP, et al. Patency of stents covered with polytetrafluoroethylene in patients treated by transjugular intrahepatic portosystemic shunts: long-term results of a randomized multicentre study. Liver int 2007; DOI: 10.1111/j.1478-3231.2007.01522.x
Perarnau JM, Le Gauge A, Nicolas C, et al. Covered versus uncovered stents for transjugular intrahepatic portosystemic shunt: a randomized controlled trial. J Hepatol 2014:60:962-968.
LaBerge JM, Ferrel LD, Ring EJ, et al. Histopathologic study of stenotic and occluded transjugular intrahepatic portosystemic shunts. J Vasc interv Radiol 2993;4:779-786. 482
Jalan R, Harrison DJ, Redhead DN, et al. Transjugular intrahepatic portosystemic stent-shunt (TIPSS) occlusion and the role of biliary venous fistulae. J Hepatol1996;24:169-176.
Saxon RR, Mendel-HartvigJ, Corless CL, et al. Bile duct injury as a major cause of stenosis and occlusion in transjugular intrahepatic portosystemic shunts: comparative histopathological analysis in humans and swine. J Vasc Interv Radiol 1996;7:487-497.
Teng GJ, Bettmann MA, Hoopes PJ, et al. Transjugular intrahepatic portosystemic shunt: effect of bile leak on smooth muscle cell proliferation. Radiology 1998;208:799-805.
Krajina A, Lojik M, Chovanek V, Raupach J, Hulek P. Stent-grafts in TIPS. Abdom Imaging 2004;29:53-59.
Wittkugel O, Koops A, Habermann C, et al. Bile resistance of coated transjugular intrahepatic portosystemic shunt stents in a flow-model. Investigative Radiology 2004;39:717-722.
Clark TWI, Agarwal R, Haskal ZJ, Stavropoulos SW. The effect of initial shunt outflow position on patency of transjular intrahepatic portosystemic shunts. J Vasc Interv Radiol 2004;15:147-152.
Cura M, Cura A, Suri R, et al. Causes of TIPS dysfunction. AJR 2008; DOI: 10.2214/AJR.07.3534
Luo SH, Chu JG, Huang H, et al. Effect of initial stent position on patency of transjugular intrahepatic portosystemic shunt. World J Gastroenterol 2017;23:4779-4787.
Klasen-Sansone J, Bode J, Lanzman RS, et al. TIPS geometry infuences patency. Z Gastroenterol 2015;53:28-32. Doi.org/10.1055/s-0034-1385430
Wang X, Luo X, Zhao M, et al. Prognostic factors for acute transjugular intrahepatic portosystemic shunt occlusion using expanded polytetrafluoroethylene-covered stent. Dig Dis Sci 2022; 65:3032-3039.
Meyer C, Paar Perez AM, Chang J, et al. Cranial stent position is independently associated with the development of TIPS dysfunction. Scientific Reports 2022; doi.org/10.1038/s41598-022-07595-5
Yin K, Wang X, Zheng T. Computational hemodynamic analysis for optimal stent position in the transjugular intrahepatic portosystemic shunt procedure. J Biomechanics 2022;Doi.org/10.1016//j.jbiomech.2022.111303
Zhan PC, Li Z, Li X, et al. A nomogram to predict the risk of stent dysfunction after TIPS in patients with hepatitis B cirrhosis. Academic Radiology 2022;29:1532-1540.
Andring B, Kalva SP, Sutphin P, et al. Effect of technical parameters on transjugular intrahepatic portosystemic shunts utilizing stent grafts. World J Gastroenterol 2015;21:8110-8117.
Cho JK, Serna J, Clark TWI, et al. Impact of PTFE-covered stent position and extension on TIPS patency. Interventional Radiology 2020;45:3915-3922.
Rössle M. TIPS: 25 years later. J Hepatol 2013;59:1081-1093.
Ferral H, Banks B, Wholey M, et al. Techniques for transjugular intrahepatic portosystemic shunt revision. AJR 1998;171:1041-1047.
Haskal ZJ, Ring EJ, LaBerge JM, et al. Role of parallel transjugular intrahepatic portosystemic shunts in patients with persistent portal hypertension. Radiology 1992;185:813-817.
Dabos KJ, Stanley AJ, RedheaDN, et al. Efficacy of balloon angioplasty, restenting, and parallel shunt insertion for transjugular intrahepatic portosystemic stent-shunt (TIPSS). Minimal Invasive Therapy & Allied Technologies 1998;7:287-293.
Rössle M. Interventional treatment of Budd-Chiari syndrome. Diagnostics 2023; doi.org/10.3390/diagnostics13081458. 483
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Fuad Barakat, Martin Rössle, Peter Reimer

This work is licensed under a Creative Commons Attribution 4.0 International License.