This pilot was to evaluate if GaitSmart, a sensor based digital health rehabilitation solution, could be administered in a clinical setting, and compare patient outcomes of GaitSmart directed rehabilitation with Standard of Care (SoC) for patients after lower limb arthroplasty. The intervention group were monitored 4 times, 3 weeks apart, with GaitSmart, starting at least 6
weeks after surgery and compared to a SoC group, treated in accordance with NICE Guidelines. Each group contained sub-groups comprised of 14 hip and 8 knee patients, total 44 participants. Gait speed increased by a clinically significant amount of 0.16 m/s in both hip and knee intervention groups, compared to 0.04m/s and -0.01m/s in the hip and knee SoC groups. Hip and knee intervention compared to hip and knee SoC; Total joint angles increased by 9.9° and 11.4° compared to 5.0° and 1.4, Utility Score of the EQ5D-5L increased 0.05 and 0.01 compared to 0.13 and 0.10 and the EQ5D-5L VAS score increased by 9 and 3.7 compared to 3.6 and 5.3. For the Oxford Hip Score, the intervention group increased by 3.5 and the SoC group by 6. For the Oxford Knee Score the intervention group increased by 7.4 and the SoC group by 4.3. Patients in the intervention and SoC groups increased confidence in walking 45% and 16% respectively. The study demonstrates the GaitSmart intervention programme can be administered in outpatients with high patient satisfaction and provides clinically meaningful results for the primary outcome gait speed.
References
NHS Digital. Finalised Patient Reported Outcome Measures (PROMS) in England, for Hip and Knee Replacement Procedures (April 2020-March 2021)
Wylde, V., et al. "Patient-reported outcomes after fixed-versus mobile-bearing total knee replacement: a multi-centre randomised controlled trial using the Kinemax total knee replacement." The Journal of bone and joint surgery. British volume 90.9 (2008): 1172-1179.
Blixt S. Patient-reported Mobility Problems after Total Hip Arthroplasty. Gothenburg University https://gupea.ub.gu.se/handle/2077/45217 2017
Hanly RJ et al. Outpatient 3-D gait analysis one year after THA using a portable IMU system: bone joint j jun 2016, 98-b (supp 11) 1
Levinger P, Menz HB, Morrow HD, Perrot MA, Bartlett JR et al. Knee biomechanics early after replacement surgery predict abnormal gait patterns 12 months post operatively. Journal of Orthopaedic Research 2012 371-376
Rahman J, Tang Q, Monda M, Miles J, McCarthy I. Gait assessment as a functional outcome measure in total knee arthroplasty: a cross sectional study. BMC Musculoskeletal Disorders 2015 16:66
Shakoor, N., Block, J. A., Shott, S., and Case, J. P. (2002). Nonrandom evolution of end- stage osteoarthritis of the lower limbs. Arthritis Rheum. 46, 3185–3189. doi: 10.1002/art.10649
Kerrigan, D. C., Lee, L. W., Collins, J. J., Riley, P. O., & Lipsitz, L. A. (2001). Reduced hip extension during walking: healthy elderly and fallers versus young adults. Archives of physical medicine and rehabilitation, 82(1), 26-30.
Chen KH, Chen PC, Liu KC, Chan CT. Wearable sensor-based rehabilitation exercise assessment for knee osteoarthritis. Sensors. 2015 Feb 12;15(2):4193-211.
NICE guideline NG 157 Joint replacement (primary): hip, knee and shoulder. Published 04 June 2020 https://www.nice.org.uk/guidance/ng157
Barker KL, Room J, Knight R, et al. Home-based rehabilitation programme compared with traditional physiotherapy for patients at risk of poor outcome after knee arthroplasty: the CORKA randomised controlled trial. BMJ Open 2021;11: e052598. doi:10.1136/ bmjopen-2021- 052598
McLean SM, Burton M, Bradley L, Littlewood C. Interventions for enhancing adherence with physiotherapy: a systematic review. Man Ther 2010; 15: 514 -521.
Artz L E, Marques N, Sanderson E, Lewis E, Murray K, Parwez J, Bertram T, Beswick W, Burston A, Gooberman-Hill A, Rachael, Blom, A and Wylde, V. Effect of group‐based outpatient physiotherapy on function after total knee replacement: The ARENA randomised controlled trial. Arthritis Care and Research, 72 (6) 2020. pp. 768-777
Toro B, Nester CJ, Farren PC. The status of gait assessment among physiotherapists in the United Kingdom. Arch Phys Med Rehabil. 2003 Dec;84(12):1878-84. doi: 10.1016/s0003- 9993(03)00482-9. PMID:
Ianculescu, M., Andrei, B. and Alexandru, A. A smart assistance solution for remotely monitoring the orthopaedic rehabilitation process using wearable technology: Re. flex system. Studies in Informatics and Control, 201928(3), pp.317-326.
Bahadori S, Immins T, Wainwright TW. A review of wearable motion tracking systems used in rehabilitation following hip and knee replacement. Journal of rehabilitation and assistive technologies engineering. 2018 Apr; 5:2055668318771816.
Cagnin A, Choinière M, Bureau N, Durand M, Mezghani N, Gaudreault N & Hagemeister N (2019): A multiarm cluster randomized clinical trial of the use of knee kinesiography in the management of osteoarthritis patients in a primary care setting, Postgraduate Medicine, DOI: 10.1080/00325481.2019.1665457
Mikolajczyk T, Ciobanu I, Badea DI, Iliescu A, Pizzamiglio S, Schauer T, Seel T, Seiciu PL, Turner DL, Berteanu M. Advanced technology for gait rehabilitation: An overview. Advances in Mechanical Engineering. 2018 Jul;10(7):1687814018783627.
Lancaster, G.A., Dodd, S. and Williamson, P.R., (2004). Design and analysis of pilot studies: recommendations for good practice. Journal of evaluation in clinical practice, 10(2), pp.307-312.
NICE Quality standard QS206 Joint replacement (primary): hip, knee and shoulder. Published 29th March 2022 https://www.nice.org.uk/guidance/qs206 Heaps 2019…
Heaps J. Inertial Measurement Unit Characterisation for Gait Analysis. 3DMC 2019 Here East, London 5 –7 November 2019
McCarthy, I., Hodgins, D., Mor, A. et al. Analysis of knee flexion characteristics and how they alter with the onset of knee osteoarthritis: a case control study. BMC Musculoskelet Disord 14, 169 (2013). https://doi.org/10.1186/1471-2474-14-169
Monda M et al. Use of Inertial Measurement Units to Assess Age-Related Changes in Gait Kinematics in an Active Population. Journal of Aging and Physical Activity, 23: 18-23. 2015 69
Zügner R et al. Validation of Inertial Measurement Units with Optical tracking system in patients operated with Total Hip Arthroplasty. BMC Musculoskeletal Disorders 2019
Abellan van kan, G et al. Gait speed at usual pace as a predictor of adverse outcomes in communitydwelling older people an international academy on nutrition and aging (iana) Task force. The Journal of Nutrition, Health & Aging© Volume 13, Number 10, 2009
Callisaya ML, Blizzard L, McGinley JL, Srikanth VK. Risk of falls in older people during fast-walking--the TASCOG study. Gait Posture. 2012 Jul;36(3):510-5. doi: 10.1016/j.gaitpost.2012.05.003. Epub 2012 Jun 8. PMID: 22682610.
Oliveira CF, Vieira ER, Machado Sousa FM, Vilas-Boas JP. Kinematic Changes during Prolonged Fast-Walking in Old and Young Adults. Front Med (Lausanne). 2017 Nov 23; 4:207. doi: 10.3389/fmed.2017.00207. PMID: 29218309; PMCID: PMC5703830.
Schulz BW. A new measure of trip risk integrating minimum foot clearance and dynamic stability across the swing phase of gait. J Biomech. 2017 Apr 11; 55:107-112. doi: 10.1016/j.jbiomech.2017.02.024. Epub 2017 Feb 27. PMID: 28302314; PMCID: PMC5473159.
Mademli L, Arampatzis A. Lower safety factor for old adults during walking at preferred velocity. Age (Dordr). 2014 Jun;36(3):9636. doi: 10.1007/s11357-014-9636-1. Epub 2014 Mar 9. PMID: 24609821; PMCID: PMC4082586.Marques et al. 2017…
Marques NR, Dos Santos APML, Camilo GF, Cardoso BC, Brando ND, Hoffman J, Navega MT, de Abreu DCCL. Effect of different residential settings on gait kinematic parameters in older adults with cognitive impairment. Hum Mov Sci. 2021 Feb; 75:102747. doi: 10.1016/j.humov.2020.102747. Epub 2020 Dec 19. PMID: 33348290.
Marques NR, Hallal CZ, Spinoso DH, Morcelli MH, Crozara LF, Gonçalves M. Applying different mathematical variability methods to identify older fallers and non-fallers using gait variability data. Aging Clin Exp Res. 2017 Jun;29(3):473-481. doi: 10.1007/s40520- 016-0592-8. Epub 2016 Jun 2. PMID:
Marques NR, Spinoso DH, Cardoso BC, Moreno VC, Kuroda MH, Navega MT. Is it possible to predict falls in older adults using gait kinematics? Clin Biomech (Bristol, Avon). 2018 Nov; 59:15-18. doi: 10.1016/j.clinbiomech.2018.08.006. Epub 2018 Aug 11. PMID: 30114546.
Martinez M, De Leon PL, Keeley D. Bayesian classification of falls risk. Gait Posture. 2019 Jan; 67:99-103. doi: 10.1016/j.gaitpost.2018.09.028. Epub 2018 Oct 1. PMID: 30312848.
Porta S, Martínez A, Millor N, Gómez M, Izquierdo M. Relevance of sex, age and gait kinematics when predicting fall-risk and mortality in older adults. J Biomech. 2020 May 22; 105:109723. doi: 10.1016/j.jbiomech.2020.109723. Epub 2020 Feb 28. PMID: 32151381.
Smith TO, Clarke C, Dainty JR, Watts L, Yates M, Pomeroy VM, Stanmore E, O'Neill TW, Macgregor AJ. Clinical and biomechanical factors associated with falls and rheumatoid arthritis: baseline cohort with longitudinal nested case-control study. Rheumatology (Oxford). 2022 Feb 2;61(2):679-687. doi: 10.1093/rheumatology/keab388. Erratum in: Rheumatology (Oxford). 2023 Feb 03; PMID: 33905483; PMCID: PMC8824410.
Astephen, J.L., Deluzio, K.J., Caldwell, G.E. and Dunbar, M.J., 2008. Biomechanical changes at the hip, knee, and ankle joints during gait are associated with knee osteoarthritis severity. Journal of orthopaedic research, 26(3), pp.332-341.
Chmiel C, Senn O, Rosemann T, Del Prete V, Steurer-Stey C. CoCo trial: Color-coded blood pressure Control, a randomized controlled study. Patient Prefer Adherence. 2014; 8:1383- 1392. Published 2014 Oct 16. 70 doi:10.2147/PPA.S68213
Pynsent PB, Adams DJ, Disney SP. The Oxford hip and knee outcome questionnaires for arthroplasty. J Bone Joint Surg Br. 2005;87-B (2):241-248. doi:10.1302/0301-620X.87B2.15095
Hernández Alava M, Pudney S. (2017) Econometric modelling of multiple self-reports of health states: The switch from EQ-5D-3L to EQ-5D-5L in evaluating drug therapies for rheumatoid arthritis. Journal of Health Economics, 55:139-152
Hernandez Alava, M., Pudney, S., and Wailoo, A. (2020) Estimating the relationship between EQ-5D-5L and EQ-5D-3L: results from an English Population Study. Policy Research Unit in Economic Evaluation of Health and Care Interventions. Universities of Sheffield and York. Report 063
NICE health technology evaluations: the manual Process and methods (PMG36) Published: 31 January
Wainwright, Thomas W., et al. "A cycling and education intervention for the treatment of hip osteoarthritis: A quality improvement replication programme." SAGE Open Medicine 8 (2020): 2050312120946522.
Hu et al. Responsiveness and minimal clinically important difference of the EQ 5D 5L in cervical intraepithelial neoplasia: a longitudinal study. Health and Quality of Life Outcomes 2020
Beard D et al. Meaningful changes for the Oxford hip and knee scores after joint replacement surgery J Clin Epidemiol. 2015 Jan; 68(1): 73–79. doi: 10.1016/j.jclinepi.2014.08.009: 10.1016/j.jclinepi.2014.08.009
Martin-Fernandez J, Gray-Laymon P, Molina-Siguero A, et al. Cross-cultural adaptation and validation of the Spanish version of the Oxford Hip Score in patients with hip osteoarthritis. BMC Musculoskelet Disord 2017; 18: 205.
Veronese, N., Stubbs, B., Volpato, S., Zuliani, G., Maggi, S., Cesari, M., ... & Cereda, E. (2018). Association between gait speed with mortality, cardiovascular disease and cancer: a systematic review and metaanalysis of prospective cohort studies. Journal of the American Medical Directors Association, 19(11), 981-
Bolink SA, Lenguerrand E, Brunton LR, Wylde V, Gooberman-Hill R, Heyligers IC, Blom AW, Grimm B. Assessment of physical function following total hip arthroplasty: Inertial sensor-based gait analysis is
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2023 I McNamara, C. E Whitehouse, N Ward, Diana Hodgins, R Whalley

This work is licensed under a Creative Commons Attribution 4.0 International License.