The Effect of Limb Length Discrepancy and Anteversion on The Post-Operational Efficacy of Total Hip Arthroplasty
DOI:
https://doi.org/10.14738/bjhmr.103.14931Keywords:
Total hip arthroplasty, Limb length discrepancy, Anteversion, Hip replacementAbstract
Total hip replacement (THA) is a common reason for patient discontent and lawsuits against doctors. An effective technique should be used by surgeons conducting THA to reduce both anteversion and limb length discrepancy (LLD). Therefore, there is a current need for a repeatable method that effectively reduces postoperative LLD and anteversion without lengthening the surgical procedure and simple to use. While numerous preoperative and intraoperative techniques are detailed in the literature, none of them are without drawbacks. Following total hip replacement, we are providing an extensive review of literatures on limb length discrepancy and anteversion along with their effects, and various methods to prevent them. By combining preoperative and intraoperative methods, we propose that every effort should be made to reduce postoperative limb length discrepancy as well as anteversion.
References
Clark CR, Huddleston HD, Schoch III EP, Thomas BJ: Leg-length discrepancy after total hip arthroplasty. JAAOS-Journal of the American Academy of Orthopaedic Surgeons 2006, 14(1):38-45. 396
Uding A, Bloom NJ, Commean PK, Hillen TJ, Patterson JD, Clohisy JC, Harris-Hayes M: Clinical tests to determine femoral version category in people with chronic hip joint pain and asymptomatic controls. Musculoskeletal Science and Practice 2019, 39:115-122.
Kraeutler MJ, Chadayammuri V, Garabekyan T, Mei-Dan O: Femoral version abnormalities significantly outweigh effect of cam impingement on hip internal rotation. JBJS 2018, 100(3):205-210.
Audenaert EA, Peeters I, Vigneron L, Baelde N, Pattyn C: Hip morphological characteristics and range of internal rotation in femoroacetabular impingement. The American journal of sports medicine 2012,
Botser IB, Ozoude GC, Martin DE, Siddiqi AJ, Kuppuswami S, Domb BG: Femoral anteversion in the hip: comparison of measurement by computed tomography, magnetic resonance imaging, and physical examination. Arthroscopy: The Journal of Arthroscopic & Related Surgery 2012, 28(5):619-627.
Wells J, Nepple JJ, Crook K, Ross JR, Bedi A, Schoenecker P, Clohisy JC: Femoral morphology in the dysplastic hip: three-dimensional characterizations with CT. Clinical Orthopaedics and Related Research® 2017, 475:1045-1054.
Kiernan S, Hermann KL, Wagner P, Ryd L, Flivik G: The importance of adequate stem anteversion for rotational stability in cemented total hip replacement: a radiostereometric study with ten-year followup. The bone & joint journal 2013, 95(1):23-30.
Lewinnek GE, Lewis J, Tarr R, Compere C, Zimmerman J: Dislocations after total hip-replacement arthroplasties. JBJS 1978, 60(2):217-220.
Pierchon F, Pasquier G, Cotten A, Fontaine C, Clarisse J, Duquennoy A: Causes of dislocation of total hip arthroplasty. CT study of component alignment. The Journal of bone and joint surgery British volume 1994, 76(1):45-48.
D'lima DD, Urquhart AG, Buehler KO, Walker RH, COLWELL CW: The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. JBJS 2000, 82(3):315-321.
Malik A, Maheshwari A, Dorr LD: Impingement with total hip replacement. JBJS 2007, 89(8):1832-1842.
Patel AB, Wagle RR, Usrey MM, Thompson MT, Incavo SJ, Noble PC: Guidelines for implant placement to minimize impingement during activities of daily living after total hip arthroplasty. The Journal of arthroplasty 2010, 25(8):1275-1281. e1271.
Sendtner E, Tibor S, Winkler R, Wörner M, Grifka J, Renkawitz T: Stem torsion in total hip replacement: CT measurements in 60 patients. Acta orthopaedica 2010, 81(5):579-582.
Lee Y, Kim T, Ha Y, Kang B, Koo K: Radiological measurement of femoral stem version using a modified Budin method. The bone & joint journal 2013, 95(7):877-880.
Biswas D, Bible JE, Bohan M, Simpson AK, Whang PG, Grauer JN: Radiation exposure from musculoskeletal computerized tomographic scans. JBJS 2009, 91(8):1882-1889.
Wang Y, Ma Y, Zhu B: Metal artifact reduction software must be used with caution. Radiology 2013,
Weber M, Lechler P, von Kunow F, Völlner F, Keshmiri A, Hapfelmeier A, Grifka J, Renkawitz T: The validity of a novel radiological method for measuring femoral stem version on anteroposterior radiographs of the hip after total hip arthroplasty. The bone & joint journal 2015, 97(3):306-311. 397
Ha Y-C, Yoo J-I, Ahn J-M, Lee Y-K, Kang Y, Koo K-H: Trans-lateral decubitus radiograph of the hip: a new view to measure the anteversion of the femoral stem. Asian Journal of Surgery 2021, 44(1):99-104.
Guenoun B, El Hajj F, Biau D, Anract P, Courpied J-P: Reliability of a new method for evaluating femoral stem positioning after total hip arthroplasty based on stereoradiographic 3D reconstruction. The Journal of arthroplasty 2015, 30(1):141-144.
Keršič M, Dolinar D, Antolič V, Mavčič B: The impact of leg length discrepancy on clinical outcome of total hip arthroplasty: comparison of four measurement methods. The Journal of arthroplasty 2014,
Rice IS, Stowell RL, Viswanath PC, Cortina GJ: Three intraoperative methods to determine limb-length discrepancy in THA. Orthopedics 2014, 37(5):e488-e495.
Affatato S, Toni A: Leg length measurement: a new method to assure the correct leg length in total hip arthroplasty. Medical engineering & physics 2000, 22(6):435-439.
Plaass C, Clauss M, Ochsner PE, Ilchmann T: Influence of leg length discrepancy on clinical results after total hip arthroplasty-a prospective clinical trial. Hip international 2011, 21(4):441-449.
Konyves A, Bannister G: The importance of leg length discrepancy after total hip arthroplasty. The Journal of bone and joint surgery British volume 2005, 87(2):155-157.
Khanduja V, Tek V, Scott G: The effect of a neck-retaining femoral implant on leg-length inequality following total hip arthroplasty: a radiological study. The Journal of Bone and Joint Surgery British volume 2006, 88(6):712-715.
Parvizi J, Sharkey PF, Bissett GA, Rothman RH, Hozack WJ: Surgical treatment of limb-length discrepancy following total hip arthroplasty. JBJS 2003, 85(12):2310-2317.
Ranawat CS, Rodriguez J: Functional leg-length inequality following total hip arthroplasty. The Journal of arthroplasty 1997, 12(4):359-364.
Heaver C, St Mart J-P, Nightingale P, Sinha A, Davis ET: Measuring limb length discrepancy using pelvic radiographs: the most reproducible method. Hip International 2013, 23(4):391-394.
Gurney B: Leg length discrepancy. Gait & posture 2002, 15(2):195-206.
McWilliams AB, Grainger AJ, O'Connor PJ, Redmond AC, Stewart TD, Stone MH: A review of symptomatic leg length inequality following total hip arthroplasty. Hip International 2013, 23(1):6-14.
Woolson ST, Hartford JM, Sawyer A: Results of a method of leg-length equalization for patients undergoing primary total hip replacement. The Journal of arthroplasty 1999, 14(2):159-164.
Meermans G, Malik A, Witt J, Haddad F: Preoperative radiographic assessment of limb-length discrepancy in total hip arthroplasty. Clinical Orthopaedics and Related Research® 2011, 469:1677-1682.
Tipton SC, Sutherland JK, Schwarzkopf R: The assessment of limb length discrepancy before total hip arthroplasty. The Journal of arthroplasty 2016, 31(4):888-892.
Sayed-Noor AS, Hugo A, Sjödén GO, Wretenberg P: Leg length discrepancy in total hip arthroplasty: comparison of two methods of measurement. International orthopaedics 2009, 33:1189-1193.
Gogia PP, Braatz JH: Validity and reliability of leg length measurements. Journal of Orthopaedic & Sports Physical Therapy 1986, 8(4):185-188. 398
Beattie P, Isaacson K, Riddle DL, Rothstein JM: Validity of derived measurements of leg-length differences obtained by use of a tape measure. Physical therapy 1990, 70(3):150-157.
Wylde V, Whitehouse S, Taylor A, Pattison G, Bannister G, Blom A: Prevalence and functional impact of patient-perceived leg length discrepancy after hip replacement. International orthopaedics 2009, 33:905-909.
White T, Dougall T: Arthroplasty of the hip: leg length is not important. The Journal of Bone and Joint Surgery British volume 2002, 84(3):335-338.
Maloney WJ, Keeney JA: Leg length discrepancy after total hip arthroplasty. The Journal of arthroplasty 2004, 19(4):108-110.
Bhave A, Paley D, Herzenberg JE: Improvement in gait parameters after lengthening for the treatment of limb-length discrepancy. JBJS 1999, 81(4):529-534.
Della Valle AG, Slullitel G, Piccaluga F, Salvati EA: The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. The Journal of arthroplasty 2005, 20(1):51-58.
Woolson ST, HARRIS WH: A method of intraoperative limb length measurement in total hip arthroplasty. Clinical Orthopaedics and Related Research® 1985, 194:207-210.
Matsuda K, Nakamura S, Matsushita T: A simple method to minimize limb-length discrepancy after hip arthroplasty. Acta orthopaedica 2006, 77(3):375-379.
Eggli S, Pisan M, Müller M: The value of preoperative planning for total hip arthroplasty. The Journal of bone and joint surgery British volume 1998, 80(3):382-390.
Capello W: Preoperative planning of total hip arthroplasty. Instructional Course Lectures 1986, 35:249-
Knight JL, Atwater RD: Preoperative planning for total hip arthroplasty: quantitating its utility and precision. The Journal of arthroplasty 1992, 7:403-409.
Hofmann AA, Bolognesi M, Lahav A, Kurtin S: Minimizing leg-length inequality in total hip arthroplasty: use of preoperative templating and an intraoperative x-ray. AMERICAN JOURNAL OF ORTHOPEDICS-BELLE MEAD- 2008, 37(1):18.
Halai M, Gupta S, Gilmour A, Bharadwaj R, Khan A, Holt G: The Exeter technique can lead to a lower incidence of leg-length discrepancy after total hip arthroplasty. The Bone & Joint Journal 2015,
Sarin VK, Pratt WR, Bradley GW: Accurate femur repositioning is critical during intraoperative total hip arthroplasty length and offset assessment. The Journal of arthroplasty 2005, 20(7):887-891.
Ng VY, Kean JR, Glassman AH: Limb-length discrepancy after hip arthroplasty. JBJS 2013, 95(15):1426-
Kayani B, Pietrzak J, Hossain FS, Konan S, Haddad FS: Prevention of limb length discrepancy in total hip arthroplasty. British Journal of Hospital Medicine 2017, 78(7):385-390.
Desai AS, Dramis A, Board TN: Leg length discrepancy after total hip arthroplasty: a review of literature. Current reviews in musculoskeletal medicine 2013, 6:336-341.
Bose WJ: Accurate limb-length equalization during total hip arthroplasty. Orthopedics 2000, 23(5):433.
Naito M, Ogata K, Asayama I: Intraoperative limb length measurement in total hip arthroplasty. International orthopaedics 1999, 23:31-33.
Shiramizu K, Naito M, Shitama T, Nakamura Y, Shitama H: L-shaped caliper for limb length measurement during total hip arthroplasty. The Journal of bone and joint surgery British volume 2004, 86(7):966-969.
Jasty M, Webster W, Harris W: Management of limb length inequality during total hip replacement. Clinical Orthopaedics and Related Research® 1996, 333:165-171.
Ranawat CS, Rao RR, Rodriguez JA, Bhende HS: Correction of limb-length inequality during total hip arthroplasty. The Journal of arthroplasty 2001, 16(6):715-720.
Desai A, Board T: A simple intra operative technique to avoid limb length discrepancy in total hip arthroplasty. In: Orthopaedic Proceedings: 2010: The British Editorial Society of Bone & Joint Surgery; 2010: 394-394.
Mihalko WM, Phillips MJ, Krackow KA: Acute sciatic and femoral neuritis following total hip arthroplasty: a case report. JBJS 2001, 83(4):589.
Barbier O, Ollat D, Versier G: Interest of an intraoperative limb-length and offset measurement device in total hip arthroplasty. Orthopaedics & Traumatology: Surgery & Research 2012, 98(4):398-404.
Cao L, Tan L, Wu C, Lin X, Guo Y, Luo X, Liu S: Effect of reformative acetabular centralization technology on leg-length inequality in total hip arthroplasty. Zhongguo xiu fu Chong Jian wai ke za zhi= Zhongguo Xiufu Chongjian Waike Zazhi= Chinese Journal of Reparative and Reconstructive Surgery 2014,
Clave A, Sauleau V, Cheval D, Williams T, Lefevre C, Stindel E: Can computer-assisted surgery help restore leg length and offset during THA? A continuous series of 321 cases. Orthopaedics & Traumatology: Surgery & Research 2015, 101(7):791-795.
Papadopoulos DV, Koulouvaris P, Aggelidakis GC, Tsantes AG, Lykissas MG, Mavrodontidis A: Intraoperative measurement of limb lengthening during total hip arthroplasty. Indian journal of orthopaedics 2017, 51:162-167.
Lakshmanan P, Ahmed SM, Hansford RG, Woodnutt DJ: Achieving the required medial offset and limb length in total hip arthroplasty. Acta Orthopædica Belgica 2008, 74(1):49.
Sathappan SS, Ginat D, Patel V, Walsh M, Jaffe WL, Di Cesare PE: Effect of anesthesia type on limb length discrepancy after total hip arthroplasty. The Journal of arthroplasty 2008, 23(2):203-209.
Kanazawa M, Nakashima Y, Hamai S, Hirata M, Iwamoto Y: Is a stem version on the crosstable lateral radiograph accurate in total hip arthroplasty? The Journal of Arthroplasty 2016, 31(6):1356-1360.
Woerner ML, Weber M, Craiovan BS, Springorum HR, Grifka J, Renkawitz TF: Radiographic assessment of femoral stem torsion in total hip arthroplasty-a comparison of a caput-collum-diaphyseal angle-based technique with the budin view. The Journal of Arthroplasty 2016, 31(5):1117-1122.
Lechler P, Frink M, Gulati A, Murray D, Renkawitz T, Bücking B, Ruchholtz S, Boese CK: The influence of hip rotation on femoral offset in plain radiographs. Acta orthopaedica 2014, 85(4):389-395.
Esposito CI, Miller TT, Lipman JD, Carroll KM, Padgett DE, Mayman DJ, Jerabek SA: Biplanar low-dose radiography is accurate for measuring combined anteversion after total hip arthroplasty. HSS Journal® 2020, 16(1):23-29.
Ogata K, Goldsand EM: A simple biplanar method of measuring femoral anteversion and neck-shaft 400 angle. JBJS 1979, 61(6):846-851.
Hermann KL, Egund N: Measuring anteversion in the femoral neck from routine radiographs. Acta Radiologica 1998, 39(4):410-415.
Norman O: ROENTGENOGRAPHIC DETERMINATION OF THE ROTATION POSITION OF THE FEMORAL PORTION OF THE HIP-PROSTHESIS. In: ACTA ORTHOPAEDICA SCANDINAVICA: 1979: SCANDINAVIAN UNIVERSITY PRESS PO BOX 2959 TOYEN, JOURNAL DIVISION CUSTOMER …; 1979: 349-349.
Luthringer TA, Vigdorchik JM: Reproducing the Proximal Femur Anatomy: 3D Preoperative Planning and Custom Cutting Guides. Personalized Hip and Knee Joint Replacement 2020:87-97.
Schneider AK, Pierrepont JW, Hawdon G, McMahon S: Clinical accuracy of a patient-specific femoral osteotomy guide in minimally-invasive posterior hip arthroplasty. Hip International 2018, 28(6):636-
Pierrepont J, Riddell W, Miles B, Baré J, Shimmin A: Clinical accuracy of a patient-specific guide for delivering a planned femoral neck osteotomy. In: Orthopaedic Proceedings: 2016: The British Editorial Society of Bone & Joint Surgery; 2016: 131-131.
Ito H, Tanaka S, Tanaka T, Oshima H, Tanaka S: A patient-specific instrument for femoral stem placement during total hip arthroplasty. Orthopedics 2017, 40(2):e374-e377.
Zhang Y, Rao Z, Zhang J, Li S, Chang S, Sun Y: 3D printed guides and preoperative planning for uncemented stem anteversion reconstruction during hip arthroplasty: a pilot study. BioMed Research International 2021, 2021:1-8.
Reitman R, Pierrepont J, Shimmin A, McMahon S, Kerzhner E: Accurate reproduction of femoral Centre of rotation using 3d templating and a PSI guide. In: Orthopaedic Proceedings: 2017: The British Editorial Society of Bone & Joint Surgery; 2017: 109-109.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2023 Shashi Ranjan Tiwari, Saroj Singh, Radheshyam Gupta, Liming Cheng

This work is licensed under a Creative Commons Attribution 4.0 International License.