The Use of PEEK in Implantology: A Narrative Review
DOI:
https://doi.org/10.14738/jbemi.96.13369Keywords:
Polyetheretherketone (PEEK), dental implants, biomaterials, dental applications.Abstract
Purpose: The present paper reviewed the literature on PEEK and its applications in implant dentistry. Materials and Methods: In vivo in human and animal models, in vitro studies, case reports and cases series that evaluated the use of PEEK in implantology were included in this narrative review. Results: There are ever more studies on the best way to apply PEEK in implant dentistry. The mechanical properties of PEEK, which are close to that of bone tissue, are its strength. However, its low osteointegration capacity and surface bio-inertness have limited its clinical translation. PEEK cannot be used as a dental implant. However, some studies have shown that this material could be used for guided bone regeneration; implant abutments for interim restorations, impression devices, or a crown framework. Conclusion: Further research, including in vivo and clinical studies, is needed to determine the feasibility, long-term performance and appropriate indication for this biomaterial.
References
Feldman D. Engineering thermoplastics-properties and applications. J Polym Sci Part C Polym Lett. 1986;24:293-294.
Preis V, Hahnel S, Behr M, Bein L, Rosentritt M. In-vitro fatigue and fracture testing of CAD/CAM-materials in implant-supported molar crowns. Dent Mater. 2017;33:427-433.
Bathala L, Majeti V, Rachuri N, Singh N, Gedela S. The Role of Polyether Ether Ketone (Peek) in Dentistry - A Review. J Med Life. 2019 ;12:5-9.
Papathanasiou I, Kamposiora P, Papavasiliou G, Ferrari M. The use of PEEK in digital prosthodontics: A narrative review. BMC Oral Health. 2020;20:217.
Zoidis P, Papathanasiou I, Polyzois G. The Use of a Modified Poly-Ether-Ether-Ketone (PEEK) as an Alternative Framework Material for Removable Dental Prostheses. A Clinical Report. J Prosthodont. 2016;25:580-584.
Zoidis P, Papathanasiou I. Modified PEEK resin-bonded fixed dental prosthesis as an interim restoration after implant placement. J Prosthet Dent. 2016;116:637-641.
Benli M, Eker Gümüş B, Kahraman Y, Gökçen-Rohlig B, Evlioğlu G, Huck O, et al. Surface roughness and wear behavior of occlusal splint materials made of contemporary and high-performance polymers. Odontology. 2020;108:240-250.
Sarot JR, Contar CMM, Cruz ACC Da, De Souza Magini R. Evaluation of the stress distribution in CFR-PEEK dental implants by the three-dimensional finite element method. J Mater Sci Mater Med. 2010;21:2079-2085.
El Awadly TA, Wu G, Ayad M, Radi IAW, Wismeijer D, Abo El Fetouh H, et al. A histomorphometric study on treated and untreated ceramic filled PEEK implants versus titanium implants: Preclinical in vivo study. Clin Oral Implants Res. 2020;31:246-254.
Chaturvedi TP. Allergy related to dental implant and its clinical significance. Clin Cosmet Investig Dent. 2013;19:57-61. 17
Cosyn J, Thoma DS, Hämmerle CHF, De Bruyn H. Esthetic assessments in implant dentistry: objective and subjective criteria for clinicians and patients. Periodontology 2000. 2017;73:193-202.
Koch FP, Weng D, Krämer S, Biesterfeld S, Jahn-Eimermacher A, Wagner W. Osseointegration of one-Piece zirconia implants compared with a titanium implant of identical design: A histomorphometric study in the dog. Clin Oral Implants Res. 2010;21:350-356.
Ma R, Tang T. Current strategies to improve the bioactivity of PEEK. Int J Mol Sci. 2014;15:5426-5445.
Elias CN, Meirelles L. Improving osseointegration of dental implants. Expert Rev Med Devices. 2010;7:241-256.
Borie M, Lecloux G, Bosshardt D, Haugen HJ, Lambert F, Bacevic M. Peri-implant soft tissue integration in humans – influence of materials: A study protocol for a randomised controlled trial and a pilot study results. Contemp Clin Trials Commun. 2020;19:100643.
Hermann JS, Buser D, Schenk RK, Higginbottom FL, Cochran DL. Biologic width around titanium implants. A physiologically formed and stable dimension over time. Clin Oral Implants Res. 2000;11:1-11.
Najeeb S, Zafar MS, Khurshid Z, Siddiqui F. Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics. J Prosthodont Res. 2016;60:12-19.
Schwitalla AD, Spintig T, Kallage I, Müller WD. Pressure behavior of different PEEK materials for dental implants. J Mech Behav Biomed Mater. 2016;54:295-304.
Ferguson SJ, Visser JMA, Polikeit A. The long-term mechanical integrity of non-reinforced PEEK-OPTIMA polymer for demanding spinal applications: Experimental and finite-element analysis. Eur Spine J. 2006;15:149-156.
Schwitalla AD, Abou-Emara M, Spintig T, Lackmann J, Müller WD. Finite element analysis of the biomechanical effects of PEEK dental implants on the peri-implant bone. J Biomech. 2015;48:1-7.
Lee WT, Koak JY, Lim YJ, Kim SK, Kwon HB, Kim MJ. Stress shielding and fatigue limits of poly-ether-etherketone dental implants. J Biomed Mater Res - Part B Appl Biomater. 2012;100 B:1044-1052.
Bataineh K, Al Janaideh M. Effect of different biocompatible implant materials on the mechanical stability of dental implants under excessive oblique load. Clin Implant Dent Relat Res. 2019;21:1206-1217.
Sunarso, Tsuchiya A, Fukuda N, Toita R, Tsuru K, Ishikawa K. Effect of micro-roughening of poly(ether ether ketone) on bone marrow derived stem cell and macrophage responses, and osseointegration. J Biomater Sci Polym. 2018;29:1375-1388.
Sunarso, Tsuchiya A, Toita R, Tsuru K, Ishikawa K. Enhanced osseointegration capability of poly(Ether ether ketone) via combined phosphate and calcium surface-functionalization. Int J Mol Sci. 2020;21:198.
Ortega-Martínez J, Delgado LM, Ortiz-Hernández M, Punset M, Cano-Batalla J, Roig Cayon M, et al. In vitro assessment of PEEK and titanium implant abutments: Screw loosening and microleakage evaluations under dynamic mechanical testing. J Prosthet Dent. 2020;S0022-3913(20)30687-9.
Hahnel S, Wieser A, Lang R, Rosentritt M. Biofilm formation on the surface of modern implant abutment materials. Clin Oral Implants Res. 2015;26:1297-1301.
Caballé-Serrano J, Chappuis V, Monje A, Buser D, Bosshardt DD. Soft tissue response to dental implant closure caps made of either polyetheretherketone (PEEK) or titanium. Clin Oral Implants Res. 2019;30:808-816.
Rea M, Ricci S, Ghensi P, Lang NP, Botticelli D, Soldini C. Marginal healing using Polyetheretherketone as healing abutments: an experimental study in dogs. Clin Oral Implants Res. 2017;28:e46-50.
Ghodsi S, Zeighami S, Azad M. Comparing Retention and Internal Adaptation of Different Implant-Supported, Metal-Free Frameworks. Int J Prosthodont. 2018;31:475-477.
Cabello-Domínguez G, Pérez-López J, Veiga-López B, González D, Revilla-León M. Maxillary zirconia and mandibular composite resin-lithium disilicate–modified PEEK fixed implant-supported restorations for a completely edentulous patient with an atrophic maxilla and mandible: A clinical report. J Prosthet Dent.
Maló P, de Araújo Nobre M, Moura Guedes C, Almeida R, Silva A, Sereno N, et al. Short-term report of an ongoing prospective cohort study evaluating the outcome of full-arch implant-supported fixed hybrid polyetheretherketone-acrylic resin prostheses and the All-on-Four concept. Clin Implant Dent Relat Res. 2018;20:692-702.
Mounir M, Shalash M, Mounir S, Nassar Y, El Khatib O. Assessment of three dimensional bone augmentation of severely atrophied maxillary alveolar ridges using prebent titanium mesh vs customized poly-ether-ether-ketone (PEEK) mesh: A randomized clinical trial. Clin Implant Dent Relat Res. 2019;21:960-967.
Arcuri L, Pozzi A, Lio F, Rompen E, Zechner W, Nardi A. Influence of implant scanbody material, position and operator on the accuracy of digital impression for complete-arch: A randomized in vitro trial. J Prosthodont Res. 2020;64:128-136.
Yue Q, Yilmaz B, Abou-Ayash S, Zimmermann P, Brägger U, Schimmel M. Use of an attachment system with angulated abutments and polyetheretherketone inserts to retain a maxillary overdenture: A clinical report. J Prosthet Dent. 2020;124:129-134.
Abdraboh A, Elsyad M, Mourad S, Alameldeen H. Milled Bar with PEEK and Metal Housings for Inclined Implants Supporting Mandibular Overdentures: 1-Year Clinical, Prosthetic, and Patient-Based Outcomes. Int J Oral Maxillofac Implants. 2020;35:982-989. FIGURES
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2022 Zeineb Hamdi, Rosario Cedeño Salazar, María Arregui, Jordi Ortega-Martínez

This work is licensed under a Creative Commons Attribution 4.0 International License.