Safety and Effect of Magnetic Resonance Imaging

Authors

  • Ghazi Owaidah Aljohani Senior Technologist, Yanbu General Hospital Ministry of Health, Saudi Arabia

DOI:

https://doi.org/10.14738/jbemi.95.12753

Abstract

This article reviews the safety considerations and biological effects of magnetic resonance imaging (MRI). It notes that the growing use of MRI as a diagnostic tool, and the increasing number of patients with implanted cardiovascular and other devices, require medical workers to receive MRI safety training, and that most MR-related injuries and deaths resulted from disobeying recognized safety regulations or from outdated knowledge about implants and equipment. The article describes the three magnetic fields used by an MRI scanner and their hazards: the static magnetic field, which can attract ferromagnetic objects, cause a 'projectile effect' and affect implanted devices; radiofrequency energy, which is absorbed by the body, is measured as the specific absorption rate (SAR) and can heat tissue, wires and leads; and rapidly changing gradient fields, which can stimulate peripheral nerves, induce currents in conductive cables and leads that may lead to arrhythmias, and contribute to scanner noise that may impair hearing. It also covers patient screening, safety terminology for implants and devices, imaging after device implantation, magnetic field, radiofrequency and cryogen risks, the in vitro, in vivo and ex vivo biological effects of static, gradient and radiofrequency fields, and SAR limits. The article advises consulting detailed safety sources, such as specialist websites, reference manuals or manufacturer information, before scanning any patient.

Abstract prepared by the editorial office from the full text of the article; the authors did not supply one.

References

Balmer, C., Gass, M., Dave, H., Duru, F., & Luechinger, R. (2019). Magnetic resonance imaging of patients with epicardial leads: in vitro evaluation of temperature changes at the lead tip. Journal of Interventional Cardiac Electrophysiology, 56(3), 321-326.

Callahan, M. J., MacDougall, R. D., Bixby, S. D., Voss, S. D., Robertson, R. L., & Cravero, J. P. (2018). Ionizing radiation from computed tomography versus anesthesia for magnetic resonance imaging in infants and children: patient safety considerations. Pediatric radiology, 48(1), 21-30.

Chandra, T., Chavhan, G. B., Sze, R. W., Swenson, D., Holowka, S., Fricke, S., ... & Iyer, R. S. (2019). Practical considerations for establishing and maintaining a magnetic resonance imaging safety program in a pediatric practice. Pediatric radiology, 49(4), 458-468.

Fishman, P. S., Elias, W. J., Ghanouni, P., Gwinn, R., Lipsman, N., Schwartz, M., ... & Eisenberg, H. M. (2018). Neurological adverse event profile of magnetic resonance imaging–guided focused ultrasound thalamotomy for essential tremor. Movement Disorders, 33(5), 843-847.

Gesu, E., Colombo, G., & Moffat, J. V. (2018). Assessing the safety of magnetic resonance imaging in cardiac device carriers. Internal and Emergency Medicine, 13(6), 933-935.

Gill, T. J., Safran, M., Mandelbaum, B., Huber, B., Gambardella, R., & Xerogeanes, J. (2018). A prospective, blinded, multicenter clinical trial to compare the efficacy, accuracy, and safety of in-office diagnostic arthroscopy with magnetic resonance imaging and surgical diagnostic arthroscopy. Arthroscopy: The Journal of Arthroscopic & Related Surgery, 34(8), 2429-2435.

Jaimes, C., Biaggotti, D., Sreedher, G., Chaturvedi, A., Moore, M. M., & Danehy, A. R. (2021). Magnetic resonance imaging in children with implants. Pediatric Radiology, 51(5), 748-759.

Kamath, A. A., Friedman, D. D., Akbari, S. H. A., Kim, A. H., Tao, Y., Luo, J., & Leuthardt, E. C. (2019). Glioblastoma treated with magnetic resonance imaging-guided laser interstitial thermal therapy: safety, efficacy, and outcomes. Neurosurgery, 84(4), 836-843.

Kazmirczak, F., Nijjar, P. S., Zhang, L., Hughes, A., Chen, K. H. A., Okasha, O., ... & Shenoy, C. (2019). Safety and prognostic value of regadenoson stress cardiovascular magnetic resonance imaging in heart transplant recipients. Journal of Cardiovascular Magnetic Resonance, 21(1), 1-8.

Kennedy, E. D., Simunovic, M., Jhaveri, K., Kirsch, R., Brierley, J., Drolet, S., ... & Baxter, N. N. (2019). Safety and feasibility of using magnetic resonance imaging criteria to identify patients with “good prognosis” rectal cancer eligible for primary surgery: the phase 2 nonrandomized QuickSilver clinical trial. JAMA oncology, 5(7), 961-966.

Kihlberg, J., Hansson, B., Hall, A., Tisell, A., & Lundberg, P. (2022). Magnetic resonance imaging incidents are severely underreported: a finding in a multicentre interview survey. European radiology, 32(1), 477-488.

Kinney, B. M., & Lozanova, P. (2019). High intensity focused electromagnetic therapy evaluated by magnetic resonance imaging: Safety and efficacy study of a dual tissue effect based non-invasive abdominal body shaping. Lasers in surgery and medicine, 51(1), 40-46.

Li, Y., Wang, J., Zhang, W., & Hu, S. (2021). Comparison Study between the Second and First Editions of ISO/TS 10974-Assessment of the Safety of Magnetic Resonance Imaging for Patients with an Active Implantable Medical Device. Zhongguo yi Liao qi xie za zhi= Chinese Journal of Medical Instrumentation, 45(1), 90-95.

Munawar, D. A., Chan, J. E., Emami, M., Kadhim, K., Khokhar, K., O’Shea, C., ... & Lau, D. H. (2020). Magnetic resonance imaging in non-conditional pacemakers and implantable cardioverter-defibrillators: a systematic review and meta-analysis. EP Europace, 22(2), 288-298.

Aljohani, G. O. (2022). Safety and Effect of Magnetic Resonance Imaging. British Journal of Healthcare and Medical Research, 9(5). 109-119.

Padmanabhan, D., Farwati, M., Izath, A., Al-Masry, A., Kella, D., Gamero, S., ... & Friedman, P. (2019). P4126 Safety of magnetic resonance imaging in patients with non-conditional cardiac implantable electronic devices: A systematic review and meta-analysis. European Heart Journal, 40(Supplement_1), ehz745-0698.

Padmanabhan, D., Kella, D. K., Deshmukh, A. J., Mulpuru, S. K., Mehta, R. A., Dalzell, C. M., ... & Friedman, P. A. (2019). Safety of thoracic magnetic resonance imaging for patients with pacemakers and defibrillators. Heart rhythm, 16(11), 1645-1651.

Padmanabhan, D., Kella, D. K., Mehta, R., Kapa, S., Deshmukh, A., Mulpuru, S., ... & Friedman, P. A. (2018). Safety of magnetic resonance imaging in patients with legacy pacemakers and defibrillators and abandoned leads. Heart Rhythm, 15(2), 228-233.

Parashar, N., Sinha, M., & Parakh, N. (2018). Safety of magnetic resonance imaging in patients with cardiac devices. Journal of the Practice of Cardiovascular Sciences, 4(1), 37-37.

Pierpoline, M., Rodich, R., Christensen, K., Naeem, A., Ramirez, R., Pimentel, R. L., ... & Sheldon, S. H. (2020). SAFETY OF MAGNETIC RESONANCE IMAGING (MRI) IN PATIENTS WITH A PACEMAKER OR DEFIBRILLATOR WITH EPICARDIAL AND/OR ABANDONED LEADS. Journal of the American College of Cardiology, 75(11_Supplement_1), 495-495.

Ponrartana, S., Moore, M. M., Chan, S. S., Victoria, T., Dillman, J. R., & Chavhan, G. B. (2021). Safety issues related to intravenous contrast agent use in magnetic resonance imaging. Pediatric radiology, 51(5), 736-747.

Schaller, R. D., Brunker, T., Riley, M. P., Marchlinski, F. E., Nazarian, S., & Litt, H. (2021). Magnetic resonance imaging in patients with cardiac implantable electronic devices with abandoned leads. JAMA cardiology, 6(5), 549-556.

Schukro, C., & Puchner, S. B. (2019). Safety and efficiency of low-field magnetic resonance imaging in patients with cardiac rhythm management devices. European Journal of Radiology, 118, 96-100.

Seifert, F. (2020). Metrology for RF safety in magnetic resonance imaging. PTB Mitteilungen, 130(2), 51-59.

Seo, J. H., Ryu, Y., & Chung, J. Y. (2022). Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging. Sensors, 22(11), 4274.

Serai, S. D., Ho, M. L., Artunduaga, M., Chan, S. S., & Chavhan, G. B. (2021). Components of a magnetic resonance imaging system and their relationship to safety and image quality. Pediatric radiology, 51(5), 716-723.

Unterweger, H., Dézsi, L., Matuszak, J., Janko, C., Poettler, M., Jordan, J., ... & Cicha, I. (2018). Dextran-coated superparamagnetic iron oxide nanoparticles for magnetic resonance imaging: Evaluation of size-dependent imaging properties, storage stability and safety. International journal of nanomedicine, 13, 1899.

Xu, Y., He, Q., Wang, M., Gao, Y., Liu, X., Li, D., ... & Wang, W. (2021). Safety and efficacy of magnetic resonance imaging-guided focused ultrasound neurosurgery for Parkinson’s disease: a systematic review. Neurosurgical Review, 44(1), 115-127.

Downloads

Published

2022-10-05

How to Cite

Aljohani, G. O. (2022). Safety and Effect of Magnetic Resonance Imaging. British Journal of Healthcare and Medical Research, 9(5), 109–119. https://doi.org/10.14738/jbemi.95.12753