Fluoride Removal in Synthetic Drinking Water by Electrocoagulation Using Aluminum Electrodes

Authors

  • Moudassirou Sedou Laboratory of Water Resources and Environmental Engineering, University of Kara. Faculty of Sciences and Technics, B.P. 404, Kara-Togo
  • Seyf-Laye Alfa-Sika Mande Laboratory of Water Resources and Environmental Engineering, University of Kara. Faculty of Sciences and Technics, B.P. 404, Kara-Togo Laboratory of Applied Hydrology and Environment University of Lome, BP. 1515, Togo Beijing Key Laboratory of Water Resources & Environmental Engineering, China University of Geosciences (Beijing), Beijing 100083, P.R. China
  • Yacouba Sanou Laboratory of Water Resources and Environmental Engineering, University of Kara. Faculty of Sciences and Technics, B.P. 404, Kara-Togo Laboratory of Analytical, Environmental and Bio-Organic Chemistry, University Joseph KI-ZERBO UFR/SEA, 03 BP 7021 Ouagadougou 03, Burkina Faso
  • Kadidja Arouna Laboratory of Water Resources and Environmental Engineering, University of Kara. Faculty of Sciences and Technics, B.P. 404, Kara-Togo

DOI:

https://doi.org/10.14738/aivp.104.12671

Keywords:

Aluminum, electrocoagulation, fluoride, removal efficiency, water treatment.

Abstract

Fluoride is recognized as an essential constituent in the human diet. Low fluoride concentration could prevent dental problem while higher fluoride concentration will cause dental and skeletal fluorosis. This study aimed to remove fluoride in synthetic drinking water by electrochemical system. It had been performed at laboratory scale using fluoride synthetic water. The process consisted to optimize the fluoride removal in drinking water using the Aluminum electrodes. The effects of operating conditions such as the initial ion fluoride concentration, current density or intensity, contact time, and NaCl amount were studied. Experimental results showed that with the initial concentration of 15 mg/L using the optimal intensity (1.5 A), an admitted residual concentration (1.5 mg/L) was observed during 45 min of electrolysis while maximum fluoride removal percentage of 100 % was achieved for 60 min. The variation of energy consumption from 1.18 to 22.35 Wh showed that the electrocoagulation can be applied using photovoltaic energy for fluoride treatment in drinking water.

References

Ahoulé, D.G., Lalanne, F., Mendret, J., Brosillon, S., Maïga, A.H., 2015. Arsenic in African Waters: A Review. Water. Air. Soil Pollut. 226, 302. https://doi.org/10.1007/s11270-015-2558-4

Alfa-Sika Mande, S.-L., Liu, M., Liu, F., Chen, H., 2009. Kinetics of the Adsorption of Chromium(VI) Ions from Water by Vegetable Precursors Treated with Sulphuric Acid. Adsorpt. Sci. Technol. 27, 965–974. https://doi.org/10.1260/0263-6174.27.10.965

Guzmán, A., Nava, J.L., Coreño, O., Rodríguez, I., Gutiérrez, S., 2016. Arsenic and fluoride removal from groundwater by electrocoagulation using a continuous filter-press reactor. Chemosphere 144, 2113–2120. https://doi.org/10.1016/j.chemosphere.2015.10.108

Harisha, R.S., Hosamani, K.M., Keri, R.S., Nataraj, S.K., Aminabhavi, T.M., 2010. Arsenic removal from drinking water using thin film composite nanofiltration membrane. Desalination 252, 75–80. https://doi.org/10.1016/j.desal.2009.10.022

Jadhav, S.V., Bringas, E., Yadav, G.D., Rathod, V.K., Ortiz, I., Marathe, K.V., 2015. Arsenic and fluoride contaminated groundwaters: A review of current technologies for contaminants removal. J. Environ. Manage. 162, 306–325. https://doi.org/10.1016/j.jenvman.2015.07.020

J. Zhu, H. Zhao, et J. Ni, « Fluoride distribution in electrocoagulation defluoridation process », Sep. Purif. Technol., Malakootian M, Mansoorian HJ, Moosazadeh M (2010) Performance evaluation of electrocoagulation process using iron-rod electrodes for removing hardness from drinking water. Desalination 255:67–71. https ://doi.org/10.1016/j.desal .2010.01.01.

Melila, M., 2013. Bioaccumulation du cadmium, du plomb et du fluor et conséquences biologiques sur l’Homme et Sphyraena barracuida (poisson marin) dans la zone de traitement des phosphates au Togo. Thèse de Doctorat, Université de Lomé, Togo.

Merzouk B., Gourich B., Sekki A., Madani K., Chibane M. Removal turbidity and separation of heavy metals using electrocoagulation–electroflotation technique: a case study. J. Hazard. Mater. 2009; 164: 215–222.

M. Emamjomeh, M. Sivakumar, Fluorideremoval by a continuous flow electrocoagulation reactor, Journal of Environmental Management 90 (2009) 1204–1212.

M. M. Emamjomeh et M. Sivakumar, « An empirical model for defluoridation by batch monopolar electrocoagulation/flotation (ECF) process », J. Hazard. Mater., vol. 131, no 1-3, p. 118-125, 2006.

M.Y.A. Mollah, R. Schennach, J.R. Parga, D.L. Cocke, Electrocoagulation (EC) — science and applications, J. Hazard. Mater. 84 (2001) 29–41

Ouro-Sama, K., Solitoke, H.D., Gnandi, K., Afiademanyo, K.M., Bowessidjaou, E.J., 2014. Évaluation et risques sanitaires de la bioaccumulation de métaux lourds chez des espèces halieutiques du système lagunaire togolais. VertigO - Rev. Électronique En Sci. Environ. https://doi.org/10.4000/vertigo.15093

Palahouane B., Drouiche N., Aoudj S., Bensadok K. Cost-effective electrocoagulation process for the remediation of fluoride from pretreated photovoltaic wastewater. J. Ind. Eng. Chem. 2015; 22:127–131.

Holt, P.K., Barton, G.W. and Mitchell, C.A. (2005) The Future for Electrocoagulation as a Localised Water Treatment Technology. Chemosphere, 59, 355-367. https://doi.org/10.1016/j.chemosphere.2004.10.023

Shan, Y., Mehta, P., Perera, D., Varela, Y., 2019. Cost and Efficiency of Arsenic Removal from Groundwater: A Review (No. UNU-INWEH Report Series, Issue 05). United Nations University-Institute for Water, Environment and Health, Hamilton, Canada.

Tanouayi, G., Gnandi, K., Ouro-Sama, K., Aduayi-Akue, A.A., Ahoudi, H., Nyametso, Y., Solitoke, H.D., 2016. Distribution of Fluoride in the Phosphorite Mining Area of Hahotoe–Kpogame (Togo). J. Health Pollut. 6, 84–94. https://doi.org/10.5696/2156-9614-6.10.84

WHO, 2011. Guidelines for Drinking-water Quality, 4th ed. ed.

Sailaja Kumari Battula, Jyostna Cheukuri, Raman N. V. V. S. S, Himabindu .V, Bhagawan. D. Effective removal of fluoride from ground water using electro-coagulation. Int. Journal of Engineering Research and Applications. 2014, pp.439-445.

Downloads

Published

2022-08-06

How to Cite

Sedou, M., Mande, S.-L. A.-S., Sanou, Y., & Arouna, K. (2022). Fluoride Removal in Synthetic Drinking Water by Electrocoagulation Using Aluminum Electrodes. European Journal of Applied Sciences, 10(4), 429–438. https://doi.org/10.14738/aivp.104.12671