Dosimetry Evaluation of Conventional Radiology Examinations in Adults in Benin
DOI:
https://doi.org/10.14738/aivp.1401.19783Keywords:
conventional radiography, dosimetry evaluation, diagnostic reference levels, BeninAbstract
Introduction and objective: Exposure to ionizing radiation raises concerns regarding radiation protection. The objective of this study was to evaluate the entry dose of X-rays during conventional radiography examinations in adult patients in Benin. Methods: This was a cross-sectional study conducted over an eleven-month period, from January to November 2025. The study was carried out in 34 healthcare facilities distributed across the national territory and equipped with functional conventional radiography units. Diagnostic Reference Levels (DRLs) were defined as the 75th percentile of entry dose (ED) and Dose–Area Product (DAP) values for each type of examination. Results: Pulmonary diseases were the most frequently investigated conditions among adult patients, with 966 patients examined, representing 27.52% of all examination indications. Posteroanterior chest radiography accounted for 34.8% of the examinations performed. The national 75th centile values (DRLs) of the entry dose (mGy) by examination type were 0.70, 17.28, 2.35, and 3.63 for chest, lumbar spine, cervical spine, and skull radiography, respectively. The national 75th centile values (DRLs) of dose–area product (mGy·cm²) by examination type were 1,120, 25,592, 938, and 1,438 for chest, lumbar spine, cervical spine, and skull radiography, respectively. Conclusion: The doses delivered to patients during conventional radiography examinations in Benin were significantly higher than international standards. Therefore, it is necessary to implement a process of procedural harmonization and dose optimization based on the established diagnostic reference levels.
References
United Nations Scientific Committee on the Effects of Atomic Radiation. Sources and effects of ionizing radiation. UNSCEAR 2008 Report. New York : United Nations ; 2010.
International Commission on Radiological Protection. Radiological protection in medicine. ICRP Publication 105. Ann ICRP. 2007 ; 37(6).
International Atomic Energy Agency. Diagnostic reference levels in medical imaging. IAEA Safety Reports Series No. 96. Vienna : IAEA ; 2018.
El Fahssi M, Semghouli S, Amaoui B, Jroundi L, Çaoui M. Assessment of entrance skin dose for adult patients undergoing diagnostic X-ray examinations in the Souss-Massa region of Morocco. Radioprotection. 2023 ; 58(2) :107–112.
Njoya Sylvain LAAH, Mouliom Tapouh JR, Samba O, Bintou Soumo H, Moifo B. Comparative evaluation of entrance surface doses for chest and lumbar spine radiography in three radiology departments in Yaoundé, Cameroon. J Afr Med Imaging. 2024 ;12(3) :110.
IAEA (2017) Radioprotection et sûreté radiologique dans les applications médicales des rayonnements ionisants : Guide de sûreté particulier, Bruxelles.
ICRP Publication 105. Radiological Protection in Medicine, Ann ICRP 2007; 37(6) :1-63.
IRSN. Analyse des données relatives à la mise à jour des niveaux de références diagnostiques en radiologie et en médecine nucléaire : Bilan 2019-2021. Fontenay-aux-Roses 2023 : IRSN.
International Commission on Radiological Protection (ICRP). Publication 135 : Diagnostic Reference Levels. 2017.
Muhogora WE et al. Estimation of patient doses from radiographic X-ray examinations in Tanzania. Radiat Prot Dosimetry. 2015.
Bamidele L et al. Diagnostic reference levels for common radiographic examinations in Nigeria. J Radiol Prot. 2018.
World Heath Organization (WHO). Global Health Observatory Data Repository. 2022.
European Commission. Radiation Protection No. 180 : Medical radiation exposure of the European population. Luxembourg : Publications Office of the European Union ; 2014.
Mettler FA, Huda W, Yoshizumi TT, Mahesh M. Effective doses in radiology and diagnostic nuclear medicine. Radiology. 2008; 248(1): 254-63. Scholar Publishing
European Commission. Radiation Protection No. 228 : European Diagnostic Reference Levels (DRLs). Luxembourg : Publications Office of the European Union ; 2018.
Shrimpton PC, Hillier MC, Lewis MA, Dunn M, Hart D. Doses from computed tomography (CT) examinations in the UK-2003 review (Report NRPB-W67). Chilton (UK) : National Radiological Protection Board; 2005.
Korir GK, Wambani JS, Korir IK, Tries MA, Boen PK. Establishing diagnostic reference levels for adult general radiography in Kenya. Radiat Prot Dosimetry. 2019 ;187(1) :545-552.
International Atomic Energy Agency. Positioning and Collimation in Radiography. Vienna : International Atomic Energy Agency ; 2019.